Skip to content

Bolt Loosening Causes

Why bolts loosen: transverse vibration zeroes thread friction for an instant and micro-slip starts exponential preload decay — the basis of the Junker test and of anti-loosening design.

By YF Zhichengjia engineering

Bolt Loosening Causes

Three stages

  • Early: embedding losses 5–15%
  • Mid: transverse micro-slip repeatedly defeats friction lock
  • Late: nut rotation, exponential preload loss

Countermeasures

Ranking: threadlocker or prevailing-torque nuts (change torque behaviour) > spring washers (compensate embedding) > plain spring washers (auxiliary only); combine on high vibration.

Standards basis

Basis: VDI 2230-1 (systematic calculation of bolted joints) and GB/T 16823.2-1997 (general rules for tightening of threaded fasteners) frame the analysis of preload decay and self-loosening under transverse vibration.

FAQ

Does higher torque stop loosening?
Adequate preload is a precondition, but vibration loosening needs locking devices, not more torque.

Need a spec check or 1-day sample?

Send us your drawing, spec or part code. We reply the same day on stock, MOQ, tiered pricing and lead time (1-day sampling for stock; volume 7–15 days).