Preload and clamp force
Preload vs clamp force: preload is bolt tension from tightening; clamp force is the actual compression on the joint — they differ due to embedding and creep.
Loss chain
- Embedding takes 5–15% within a minute
- Washer creep and thermal cycling add losses
- Effective clamp = preload × (1 − loss) − separation load
Getting preload right
Torque method scatters ±25–40%; measured K plus LC coating stabilisation reaches ±10%; critical joints use ultrasonic or angle control.
Standards basis
Basis: GB/T 16823.3-2010 (torque/clamp-force testing) — K factor and total friction are measured per this standard.
FAQ
How much preload?
60–75% of yield typically; aluminium bolts from measured K and material limits.
Need a spec check or 1-day sample?
Send us your drawing, spec or part code. We reply the same day on stock, MOQ, tiered pricing and lead time (1-day sampling for stock; volume 7–15 days).
Call directly: +86 135-1036-9429(Mr. Zhang (Engineering & Sales Director)) · +86 135-6073-0094(Ms. Fan (Sales Manager))